EMF
electric and magnetic field interaction.
See Also: Electromagnetic Field, EMF Meters, Inductance
-
Product
Power Line Disturbance & EMF Monitors
-
This category contains a variety of solutions for those power line disturbances situations, from simple to complex models.
-
Product
PXI Low Thermal Multiplexer, 23-Channel
40-620A-022
Multiplexer Module
The 40-620A Multiplexer module is similar to other multiplexers in Pickering range of switching modules except thermal EMF is substantially reduced to <1.5µV with 250nV thermal stability.
-
Product
Calibration
RF Test Equipment
-
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
Product
EMF Measurements Antennas
-
An isotropic antenna that allows to carry out radiated emission and environment exposure measurement (elettrosmog) to the radio frequencies in proximity of radio and television stations and repeaters for mobile telephone.
-
Product
Low Thermal EMF Relays
Series 100
-
The Pickering Series 100 is a complete range of Single-in- Line (SIL) reed relays primarily intended for direct drive from 4000B CMOS or similar low current sources. They feature a very low level of thermal EMF.
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
Consulting Services
-
Standards and Regulatory Management. Standards Development. Regulatory (FCC, FDA, Access Board). Areas of Technical Excellence: Electromagnetic Compatibility, Disability Access, Wireless Requirements, RF Safety (EMF & SAR), Product Compliance, Quality & Conformity Systems, Measurement of Electromagnetic Fields. Training - We offer a variety of course in various areas of compliance and technology. We also provide custom training, tailored to your needs, in our areas of expertise.
-
Product
Motor Starting & Control Resistors
-
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
Product
Gauss Meters
-
A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.
-
Product
EMF / RF / Radiation Meters
-
Sper Scientific EMF meters measure Electro Magnetic Frequency radiation levels. Whether you're measuring EMF emissions from electrical power lines and transmission equipment, computers, HVAC, audio/video or other electrical appliances, our meters are small and light enough to go anywhere, yet sensitive enough to detect minuscule amounts of EMF radiation.
-
Product
Temperature Measurement click board
Thermo J click
-
Thermo J click is a temperature measurement click board™, which uses a thermocouple type-J probe, connected to a PPC-SMP-J onboard connector. The active part of the Thermo J click is MCP9600 by Microchip - a thermocouple EMF to temperature converter, with 1.5°C of maximum accuracy. The onboard PCC-SMP-J connector ensures the secure connection and accurate readings for the connected thermocouple.
-
Product
LXI Low Thermal EMF Matrix 1-pole 42x33
60-510-002
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
EOL Testing of Starter-Generator Units (ISG)
-
Series test rig for starter-generator units (ISG)*High voltage test*Insulation resistance measurement*Temperature sensor control*Short circuit test*EMF test*Performance measurement*Manual loading and contacting
-
Product
EMF Detector
ElectroSensor™
-
This EMF detector is an unparalleled value that offers fast, reliable, and user-friendly measurements of electromagnetic pollution. Since man-made alternating current (AC) is different from naturally occurring EMF, some sources say that even extended exposure of as low as 2 milliGauss may be harmful. Fortunately, once EMF sources are identified with your ElectroSensor you can moderate your distance and exposure.
-
Product
EMF Testers
-
Shanghai Beha Electronics Co., Ltd.
*Handy EMF tester*Digital EMF Tester for Measurement of Magnetic Field Strength*direct display in Tesla or Gauss*Measurement Range:0...199,9 μT0...1999 mG
-
Product
PXI 23 Channel Low Thermal MUX
40-620-022
Multiplexer Module
Pickering 40-620 Multiplexer modules are similar to other Pickering Multiplexer cards except thermal EMF is substantially reduced to <1.5V with 250nV thermal stability. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC microvolt measurements.
-
Product
RF Near Field Probe Set DC to 9GHz
-
EMF & RF close field sniffer-set for use with any Spectrum Analyzer or Measurement Receiver. The EMC Near Field probe set allows for straightforward pinpointing and measurement of interference sources in electronic component groups as well as execution and monitoring of generic EMC measurement. Our RF near field probe set is especially suitable for: - Pinpointing interference sources - Estimation of interference field strength - Verification of shielding and filtering measures - Identifying faulty components - Detecting circuitry overly sensitive to interference.
-
Product
3-Axis EMF Meter Ignore/Bandpass/Analyze Powerlines
DSP-523 Gaussmeter
-
The DSP-523 uses a powerful digital signal processor that sets a new standard for AC gaussmeters. Now you can ignore powerlines, bandpass powerlines and analyze powerline harmonics, all with one simple meter.
-
Product
EMF Exposure Test
sXcTEM835
-
Tests radiofrequency electromagnetic field exposures from mobile communication devices operating in the 900 MHz region (additional frequencies upon request). The setup is based on two Crawford TEM cells that are blindly excited by a fully computer-controlled signal unit.
-
Product
EMF Fluxgate Magnetic Field Meter
LM-MP6000-EMF
-
The List-Magnetik LM-MP6000-EMF EMF fluxgate magnetic field meter (fluxgate magnetometer) can measure very weak DC and AC magnetic fields in the range of 0–400 µT (microtesla), 0–4 G (gauss), or 0–300 A/m. The device uses a fluxgate measuring probe to measure magnetic fields in the transverse direction.
-
Product
LXI EMR Low Thermal EMF Matrix 14x33
60-511-004
Matrix Switch Module
This high density 1-pole matrix has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix.
-
Product
LXI Low Thermal EMF Matrix 1-pole 44x33
60-510-021
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
Reed Relays
-
TPM Reed Relays - surface mount, high breakdown voltage, high temperature operate, high density, miniature PCB through hole, standard PCB through hole, EMF low thermal, high insulation/dry, high insulation/wet, high insulation/high voltage, DIP/dual in-line package, SIP/single in-line package, multiplexer, and more.
-
Product
Metal Foil Llow Resistance Chip Resistor
MFR (Metal foil)
-
*Low Resistance / TCR / EMF 9only FOR MnCu) / Inductance*Excellent long term stability*RoHS compliant and halogen free.*Lead free.* High precision current sensing and voltage division.
-
Product
EMF Measurements/EM Measurements/Electromagnetic Radiation
-
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.
-
Product
LXI Low Thermal EMF Matrix 1-pole 56x33
60-510-001
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
Metal Foil Low Resistance Chip Resistor
MFF
-
*Low Resistance / TCR / EMF / Inductance*Excellent long term stabilityRoHS compliant and halogen free.*Lead free.*High precision current sensing and voltage division.
-
Product
Milliohm Meters
Chroma 16502
-
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
Product
LXI EMR Low Thermal EMF Matrix 28x33
60-511-003
Matrix Switch Module
This high density 1-pole matrix has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix.
-
Product
Magnetic Radiation (Gauss Meter)
-
A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both.