  • Insulating Oil Testing

    Megger Group Ltd.

    Insulating oil in electrical power apparatus serves two primary roles, as an insulator and a coolant. As an insulating liquid, oil’s most important property is a high dielectric strength and as a cooling liquid, a low viscosity is paramount. The principal nemeses of insulating oil are oxidation, contamination (particularly moisture, which tends to lower the dielectric properties of insulating oil), and excessive temperature. These enemies are managed through design, regimented installation processes and prudent operation of the oil-filled power apparatus. At all stages of a power asset’s life, testing must be conducted to evaluate the condition of the insulating oil. In fact, for some assets, it can be argued that the oil is tested more frequently than any other component.

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

  • DC Hi-Pot Tester

    3010HP, 3025HP & 3050HP - Jabbals

    The DC Hi-Pot test is an important part and parcel of the electrical safety tests mandated by standards organization world-wide. More than 80 per cent of faults in electrical and electronic systems are due to weak insulation caused by environmental factors such as dirt, grease, temperature stress, humidity, etc that affect the dielectric strength of the insulation material.

  • Hipot Tester

    Sentinel - Seaward Electronic Ltd

    The Sentinel series of test instruments has been built to provide a cost effective, yet powerful solution to hipot testing, whether on a production line or in a laboratory environment for compliance testing purposes. With the ability to perform either 5kV AC or 6kV DC dielectric strength tests and up to 500VA AC power output the Sentinel series can aid testing to many international safety standards including IEC, EN, UL and CSA to name but a few.

  • Hipot Tests

    LXinstruments GmbH

    The hipot test (high potential test) or dielectric withstand test, is used to determine the insulation and dielectric strength. It is carried out on modules, devices and systems of protection class I + II. In this test, the insulation of the test object is subjected to greater stress by the high voltage than in normal operation. It is determined whether the insulation of all current-carrying conductors, as well as the safety distance to the enclosure, is sufficient and complies with the legal requirements under normal operating conditions.We will be happy to assist you with any questions or solutions to problems.You will find a large selection of high-voltage testers in our comprehensive shop.Questions? We are always at your disposal.

  • High Voltage Test Equipment

    SPS electronic GmbH

    With the high-voltage test devices from SPS electronic, you can carry out all high-voltage tests in accordance with standards. The devices thus enable the testing of the electrical insulation properties and dielectric strength of electrical devices of protection class I and protection class II. We offer you high-voltage testers / hipot testers for voltages in the range of up to 5,500 V AC or 6,000 V DC at a maximum of 100 mA / 200 mA.

  • High-voltage Testers

    Kharkovenergopribor Ltd.

    Operational safety and reliability of electrical equipment and cables directly depend on the dielectric strength of the insulation. Portable and mobile high-voltage testers from KharkovenErgoPribor Ltd. are used for acceptance and operational testing of substation equipment and cable lines, as well as for checking the reliability of personal electrical safety equipment. Our testers range is represented by test systems that allow conducting high-voltage tests with DC and AC voltage, testing polymer insulated cables with very low frequency, testing and locating faults in cable sheath, as well as performing the initial burning of insulation on damaged sections of cable lines.

  • High-Voltage Test Hood

    LX-HVE600 - LXinstruments GmbH

    The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • High-Voltage Test Hood

    HVE900 - LXinstruments GmbH

    The large, bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 940 * 716 * 640mm Usable test space (W * D * H) approx. 750 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • Fully Automatic Transformer Oil Test Set

    Neutronics Manufacturing Co.

    1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.

Get Help