Product
Electrochemical Workstations
-
Besides a potentiostat / galvanostat all our electrochemical workstations include also a frequency response analyzer unit (FRA) in their basic configuration. This makes each of our electrochemical workstations a highly versatile basis equipment for a multitude of electrochemical investigation methods on batteries, accumulators and fuel cells as well as on high impedance objects such as coatings and laminates. Due to their hardware extensions slots our instruments can be extended to multi purpose data acquisition and control test stands.
-
Product
Scanning Electrochemical Microscope
VS-SECM (DC And AC)
-
The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode probe or tip. The positioning system moves the probe close to the surface of the sample, within the local imaging zone. The bipotentiostat can polarize the probe only (feedback mode) or the sample and the probe independently (generator-collector mode), while measuring the resulting current(s). The probe is specially designed to have a specific tapered polish (per the RG ratio) and active radius below 100 microns. The positioning system scans the probe and charts position with measured electrochemical parameters, creating a data map of local current.
-
Product
Handheld Electrochemical Battery Analyzer
EC-Series
-
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
Product
Scanning Electrochemical Systems
-
The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.
-
Product
Electrochemical Detector
800D
-
The Model 800C series is designed for electrochemical detection. This instrument can be used for monitoring the current passing through a flow cell in liquid chromatography/electrochemistry and in-flow injection analysis, as well as other electroanalytical applications.
-
Product
Electrochemical Impedance Spectroscopy (EIS)
-
Electrochemical impedance spectroscopy (EIS) is a method for the non-destructive characterisiation of thin layers, membranes, surfaces and films. Typically a small amplitude AC voltage (or current) signal is applied to a sample while the amplitude and phase relationship of the corresponding current (or voltage) signal is monitored.
-
Product
Industrial Oxygen Transmitters with Zirconia or Electrochemical Sensors
-
The range of Oxygen Transmitters from PST are compact and robust devices that utilise zirconia, solid state ceramic or electrochemical sensing technologies to give a reliable measurement of oxygen concentration.
-
Product
Electrochemical Analyzer/Workstation
600E
-
The Model 600D series is designed for general purpose electrochemical measurements. The figure below shows the block diagram of the instrument. The system contains a fast digital function generator, high speed data acquisition circuitry, potentiostat, and a galvanostat (available only in select models).
-
Product
DigiElch Electrochemical Simulation Software
-
DigiElch 8 from ElchSoft is an electrochemical simulation program for a wide variety of systems involving charge transfer reactions, adsorption, and charge-coupled chemical reactions such as proton-coupled electron-transfer (PCET). A demonstration version of DigiElch 8 is available.
-
Product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
-
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
Product
Electrochemical Analyzer
EC Epsilon EClipse
-
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
Product
Electrochemical Converter
C800
-
The Control 800 series of electrochemical converters combines high performance digital conductivity and analog pH measurements with intuitive operation. It has been designed for easy integration into skids and panels to cover a wide range of bioprocess applications in both, conventional stainless steel and single-use systems.
-
Product
Potentiostat/Galvinostat Electrochemical Instuments
-
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
Product
Electrochemical Sensors
-
Electrochemical sensors are devices that provide real-time information about the composition of a system by connecting a chemically selective layer (recognition element) to an electrochemical transducer
-
Product
Electrochemical Measurements
-
A portable pH-meter from CHAUVIN ARNOUX is ideal for mobile applications: in the field, in the laboratory or in production. It can be used for quick, accurate, professional measurements of pH, Redox potential and temperature.
-
Product
Scanning Electro-chemical Microscope
920D
-
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.