Filter Results By:

Products

Applications

Manufacturers

Ballast

Balance the current flow to lamps.


Showing results: 1 - 15 of 35 items found.

  • Electronic Ballast Tester

    Lisun Electronics Inc.

    LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards

  • Electronic Ballast Tester

    WT5000 - Lisun Electronics Inc.

    WT5000 is the updated version of WT3000 with a super LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB/T15144-2005, GB/T17263-1998 and so on.

  • CCFL Ballast Tester

    WT2000A-CCFL - Lisun Electronics Inc.

    This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report

  • Electronic Ballast Analyzer

    WT3000 - Lisun Electronics Inc.

    • It has 8 windows to display each parameter of input and output characteristics • Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast • WT3000 has expanding analysis for envelope wave. • Symmetry analysis for envelope wave’s crest factor of lamp current • Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz • Portable with built-in chip micro-processor, particular suitable for development and spot production • RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7

  • Electronic Ballast Tester

    WT4000 - Lisun Electronics Inc.

    • Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.

  • HID Ballast Tester

    WT2000-HID - Lisun Electronics Inc.

    • Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz

  • HID Electronic Ballast

    Shanghai Yiya Electronic Instrument Co., Ltd.

    Applicable to illumination of marketplace, office illumination, home illumination, architectural illumination.

  • Ballast Water Monitoring Systems

    HF Scientific

    Ballast water is essential for safe and efficient shipping operations and stabilizing steel-hulled vessels at sea. It provides a variety of critical functions, such as maintaining balance, stability, and structural integrity on non-cargo voyages or when cargo is unloaded. Ballast water is also used to compensate for fuel and water consumption during at-sea operations.

  • Marine Ballast Water Analyzer

    9017 - OI Analytical

    Developed specifically for the demands of marine environments, OI Analytical's new Model 9017 Marine Ballast Water Analyzer was engineered to meet the stringent United States Coast Guard (USCG) standards. The 9017 monitors and controls total chlorine and residual oxidants around the clock, while connected to a Ballast Water Management System with user-programmable cycle times and alarms.

  • FLuorescent Lamp And Ballast Tester

    2210-20 - Milwaukee Electric Tool Corporation

    The Milwaukee 2210-20 Fluorescent Lighting Tester is a new to world tool that tests fluorescent lighting fixtures and cuts troubleshooting time in half. The Fluorescent Lighting Tester delivers complete Lamp, Ballast and Pin testing. Test Lamps before or after installing, and test without dismantling the fixtures.Recognized for its innovation, the 2210-20 Fluorescent Lighting Tester will dramatically improve the productivity of professional electricians and maintenance technicians. Instead of a “replace and hope” strategy, users can test their lighting fixtures faster and easier. The 2210-20 Fluorescent Lighting Tester solves a top residential, commercial and industrial application.

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Electronic Ballast Production Line Tester

    UI2000-OK - Lisun Electronics Inc.

    • Eight windows for displaying input characteristics, output characteristics, convenient for comparison and analysis. • Frequency response for testing input current up to 1 MHz, suitable for precise testing of various kind of electronic ballast. • High speed testing, finish testing input and output characteristics within 1 minute. • Portable with built-in chip micro-processor, particular suitable for development and spot production. • Parameters, waves and curves of input, output and startup can be printed. • Communicating with PC, special software provided and both Chinese version and English version available. Run in WINDOWS3.2,  WINDOW95 or WINDOWS98, nice interface between people and computer, easy to operate.

  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

  • Input Characteristic Analyzer of Electronic Ballast

    UI2001 - Lisun Electronics Inc.

    • 4 display windows for V (600V), A (2A), W, PF/Hz • THD, 0 to 39th harmonic components • Accuracy: ± (0.4% reading + 0.1% range + 1 digit) • Data and curves printable. All the data and curves can be displayed after being connected with PC

Get Help