Product
Compact Anechoic Chambers
-
If you have mmmwave or THz antenna phased-array that require Over the Air measurements, MilliBox has the equipment and tools that you need. With the help of MilliBox compact anechoic chamber system, you can plot radiation pattern , collect data from those plots, and assess your antenna performance easily and precisely.
-
Product
Anechoic chambers
-
The anechoic chambers are built up as a modular construction. Due to individual modules any size of chamber can be manufactured. Big chambers may require an outer supporting structure or alternatively the shielding material can be attached direct to the building. The absorbers are fixed to rails bars or wooden base construction which is inserted into the shielding modules.
-
Product
Large-size Hybrid Reverberation / Anechoic Chamber
F-Series
-
The F large-size hybrid Reverberation/Anechoic Chamber represents the most versatile OTA test system in the market today. With the same unique test features of their E Series RC counterparts, the F-Series can also test large form-factor devices under test (DUTs) like laptops, large TV sets, solar and trash compactors, drones, fridges or washing and vending machines, among others.
-
Product
Anechoic Chamber
EMC-3
-
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
Product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3720
-
Suitable for weak electric field resistance test, out-of-service test or digital forensics for smart phone, tablet terminal or mobile PC ! !DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
Product
Electromagnetic anechoic box/Shield box/Anechoic chamber
-
The necessity of a wireless system test has risen by the spread of recent wireless telecommunication equipment as shown in cellular phone, wireless LAN, RF-ID tag and ETC (Electronic Toll Collection system). It is necessary for a wireless test to be performed in anechoic environment in which an external noise is intercepted and a radio wave does not reflect internally. An anechoic chamber (room version of a shield box) is proper facilities but needs a wide space and a huge cost. Especially, the equipment under wireless system test on the production line can not radiate any signal radio wave outside before approval. The shield box satisfies these conditions.
-
Product
Anechoic Chambers
-
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
Product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3710HS
-
Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
Product
Anechoic Chamber
-
Beijing KeHuan Century EMC Technology Co,.LTD
(7m × 4m × 3m) RF shielding EMC laboratory (anechoic chamber) is constructed by attaching ferrite tiles and microwave absorbing materials after the RF shielding room is built (7m × 4m × 3m) The simple 3m test distance EMC laboratory can perform EMC tests in the frequency range of 30MHz-18GHz.
-
Product
Anechoic Chamber Filters
-
RF leakage through Ethernet and USB cables can destroy even the best RF enclosures and chambers. The need for filtering in the ever congested RF environment requires special filters that can pass USB 2.0 and 10/100/1000 Mbps Ethernet signals and filter out unwanted higher frequencies such as cellular and WiFi. The Adaura Technologies USB/Gigabit Filters provide one GigE and one USB 2.0 pass-through connections while filtering out other RF up to 8GHz. It has a small form factor to allow easy installation. It is a most cost effective solution for a clean chamber set up. In a typical chamber, WiFi signals are reduced to <-100dBm with this filter installed.
-
Product
Anechoic Chamber room for Automotive components
-
Anechoic Chamber room of most suitable Automotive devices EMI/EMS test of the method of ALSE, which meet the global standard like a 2004/104/EC, several emmission standard like a CISPR25 which automotive manufacturers in EU/USA refer to, Immunity standard like a ISO11452 and others for the Automotive devices.