Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing results: 1291 - 1305 of 3964 items found.

  • On-Site Oil Analyzer

    MiniLab 23 - Ametek Spectro Scientific

    With two simple tests, the MiniLab 23 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions.

  • On-Site Oil Analyzer

    MiniLab 33 - Ametek Spectro Scientific

    With three simple tests, the MiniLab 33 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions

  • On-Site Oil Analyzer

    MicroLab 40 - Ametek Spectro Scientific

    MicroLab 40 is designed primarily for fleets operating equipment with hydraulic components or heavy equipment gears and transmissions. This would include off-road mining and construction vehicles as well as over-the-road equipment with hydraulics such as bucket trucks, fire engine ladder trucks or solid waste trucks. The MicroLab 40 is also used in applications for offshore drilling equipment. In addition to the basic oil chemistry and extended elemental analysis provided with the MicroLab 30, the MicroLab 40 model includes a particle counter which provides critical analysis for cleanliness of hydraulic oils and gear oils to determine the health of those oils and mechanical condition of those components.

  • Oil In Water/Soil Analyzer

    InfraCal 2 TRANS-SP - Ametek Spectro Scientific

    The InfraCal 2 TRANS-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels using the traditional EPA methods 413.2 and 418.1 or ASTM method D7066-04 and Freon-113, hydrocarbon-free grade of perchloroethylene, AK-225, S-316 or other spectroscopic infrared transparent solvent as the extracting solvent. Since the extract is deposited into a 10 mm quartz cuvette cell with Teflon stopper, light end volatile components are retained for measurement. Accurate down to 0.1 ppm.

  • Veterinary Hematology Analyzer

    ABX Micros ESV 60 - HORIBA, Ltd.

    The Gold Standard of Veterinary Hematology Testing- Open Tube- 10 animal species- 8 or 18 parameters- 50 tests/hour- Highly compact and lightweight- Micro-sampling on whole blood: 10μL- Precise cellular identification through electronic impedance variation method- Haemoglobin measurement with photometry

  • Telecom Conformance Analyzer

    TCA 8200 - Hermon Laboratories Ltd.

    The TCA 8200 is an all-in-one conformance testing solution, according to worldwide regulatory & industry standards, for many types of telecom equipment ranging from phones, cellular phones including LTE to digital switches, PBXs and VoIP gateways.

  • Total Hydrocarbon Analyzer

    Model 4020 - Teledyne Analytical Instruments

    The Model 4020 uses a field-proven FID detector to measure THC in various streams. This instrument is ideal for monitoring hydrocarbon contamination in high purity bulk gases. When coupled with Teledyne’s unique separation column, the 4020 is also diverse enough to be applied in hazardous locations for detection of volatile hydrocarbons in cooling water for process leak detection and environmental compliance.

  • Total Hydrocarbon Analyzer

    Model 4030 - Teledyne Analytical Instruments

    The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.

  • Trace Moisture Analyzer

    Model ​8800A - Teledyne Analytical Instruments

    The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.

  • Trace Moisture Analyzer

    Model 8800P - Teledyne Analytical Instruments

    The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These s​tructural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.

  • Trace Moisture Analyzers

    Model 8800T - Teledyne Analytical Instruments

    The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. The​se structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.

  • Trace Moisture Analyzer

    Model ​8800B - Teledyne Analytical Instruments

    The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.

  • Trace Nitrogen Analyzer

    Model 2120XL​​​ - Teledyne Analytical Instruments

    ​In many argon or helium gas supply systems, the detection of trace nitrogen (N2) is essential in determining system integrity. The Model 2120XL is the new standard in this critical measurement. It provides continuous and accurate nitrogen analysis using field-proven emission spectroscopic technology in a space-saving 19” rack-mount 3U package.

  • NO / NO2 / NOX Analyzers​

    9110T Series - Teledyne Analytical Instruments

    The Model 9110T uses the proven chemiluminescence detection principle, coupled with state-of-the-art microprocessor technology to provide the sensitivity, stability and ease of use needed for ambient or dilution CEM requirements for monitoring levels of oxides of nitrogen.

  • NO / NO2 / NOX Analyzers

    9110TH Series​ - Teledyne Analytical Instruments

    The Model 9110T uses the proven chemiluminescence detection principle, coupled with state-of-the-art microprocessor technology to provide the sensitivity, stability and ease of use needed for ambient or dilution CEM requirements for monitoring levels of oxides of nitrogen.

Get Help