Showing results: 2026 - 2040 of 3937 items found.
-
Model 3000TA-XL -
Teledyne Analytical Instruments
Model 3000TA-XL is a precision, cost effective instrument specifically designed to measure trace oxygen in the 0-1 ppm region. The model provides the user with a wide variety of performance features and options to satisfy virtually any application.
-
Model 3020P -
Teledyne Analytical Instruments
The Model 3020P is a versatile microprocessor-based instrument for detecting oxygen at the percent (%) level in a variety of gases. This instrument serves as the explosion-proof, bulkhead-mount version of the 3000P, and is designed to make the task of percent oxygen analysis easier, faster and more precise than ever before. Simple menu choices, externally accessible switches and dual LCD and LED displays make setup and operation clear and quick.
-
Model 3020M -
Teledyne Analytical Instruments
The Model 3020P is a versatile microprocessor-based instrument specifically designed to detect oxygen in a variety of gases. It is a precise, cost effective instrument capable of measuring percent oxygen in as low as the 0-1% range. Drawing on the solid performance of the 3000 series control platform, the 3020M provides the user with a wide variety of features and options to satisfy virtually any application.
-
Model LGA-4000Z -
Teledyne Analytical Instruments
Teledyne’s LGA-4000Z series leverages the latest in Tunable Diode Laser Absorption Spectroscopy (TDLAS) to achieve an ultra-fast gas measurement in-line without resorting to extraction and sample conditioning. By tuning the laser to a specific absorption wavelength, based on the gas of interest, the attenuation of the light through a sample cell and the detector can be correlated to the concentration of each gas, per Beer-Lambert Law. The laser provides a narrow absorption band which minimizes the effect of interfering compounds in the process.
-
MESA-7220V2 -
HORIBA, Ltd.
The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method. A monochromatic X-ray source is used in order to obtain an ultra-low noise background which affords the best detection limits for both sulfur and chlorine.The detector window size was increased to collect more fluorescent X-rays and thus achieve lower level ppm values. This provides excellent, repeatable performance at both low and high concentrations of both elements.By adjusting the angle of the graphite crystal, the excitation beam can be measured to excite sulfur in the sample, increasing sensitivity.
-
DVS Resolution -
Surface Measurement Systems
DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.
-
VM-DBA -
W-IE-NE-R, Plein & Baus GmbH
VM-DBA is a new test and diagnostic module for VME-bus systems which visualizes activities on all VME bus lines on the set of front-panel LEDs, but also allows one to digitize individual waveforms of all these lines into 2kBit -long storage memories, for a subsequent readout via VME or USB interfaces.
-
Model T200M -
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
LocusUSA
Monitors and measures all radios on a network over-the-air (OTA) in real-time without user interventionProactively helps you manage all of your radios in your networkMultiple receivers may be networked to provide system wide coverage
-
GT4000 -
Guide Technology, Inc.
A true breakthrough in high-speed, asynchronous and serial interface test technology the GuideTech GT4000 leverages the power of CTIA continuous time-stamping technology to eliminate the need for supplemental triggers, pattern markers or clock recovery circuits. GuideTech CTIAs enable serial interface pattern verification and full jitter analysis in milliseconds for fast, automated characterization or high-throughput production test on any ATE platform, including low-cost and in-house testers.
-
AcoustoSizer II -
Colloidal Dynamics, LLC
The new AcoustoSizer IIs provides thorough characterization of concentrated colloidal dispersions. Directly measuring particle size, zeta potential, pH, conductivity, and temperature, it furnishes the most comprehensive analysis available in a single, turnkey instrument. Based on a flow-through sensor design, the AcoustoSizer IIs can be used in a laboratory batch analysis mode or connected directly to a process slipstream. Built-in syringe pumps provide automated potentiometric and volumetric titration capabilities for accurate isoelectric point and surfactant addition determination.
-
Live-Capture -
WavCapture
Live-Capture is a simple to use PC-based software tool for real-time live-sound measurements. Live-Capture measures time-domain and frequency domain simultaneously, using the program material (music and speech) with the audience present.
-
Live-Capture Pro -
WavCapture
Live-Capture is a simple to use PC-based software tool for real-time live-sound measurements. Live-Capture measures up to 8 channels of time-domain and frequency domain simultaneously, using the program material (music and speech) with the audience present. Live-Capture Pro also employ traditional MLS and Chirp measurements.
-
BusPro-I™ -
Corelis, Inc.
The BusPro-I has all the power, flexibility, and features you need to monitor and debug the I2C bus circuitry on your board. The BusPro I2C can be used to monitor and log I2C bus traffic in real-time, generate I2C transactions to communicate with peripheral components on the bus, and in-system program I2C compatible EEPROMs.
-
SpectrOil M -
Ametek Spectro Scientific
The SpectrOil M/F-W is a compact, rugged and easy to use fuel analysis spectrometer. It is designed specifically for the analysis of ash-forming contaminants in fuel such as sodium, potassium and vanadium that cause corrosion or deposits at turbine operating temperatures. It measures trace quantities of dissolved or suspended contaminant particles in a fuel sample using the time-tested and reliable rotating disc electrode (RDE) technique.