Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing results: 1966 - 1980 of 3964 items found.

  • AC / DC Digital Power Analyzer

    4016(800Vp,20Arms/200Ap) - PRODIGIT Electronics Co, Ltd.

    To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.

  • UV Fluorescence Hydrogen Sulfide Analyzer

    Model T101 - Teledyne Monitor Labs

    The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T101 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ S​oftware. ​​

  • DVB / MPEG Stream Analyzer program

    dvbsnoop - DVB Project

    dvbsnoop is a DVB / MPEG stream analyzer program, which enables you to watch (live) stream information in human readable form. Its purpose is to debug, dump or view digital stream information (e.g. digital television broadcasts) send via satellite, cable or terrestrial. Streams can be SI, PES or TS. Basically you can describe dvbsnoop as a "swiss army knife" analyzing program for DVB, MHP, DSM-CC or MPEG

  • Portable Three-Phase Meter Site Analyzer

    RW-30X / RW-31X - Radian Research, Inc.

    RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.

  • Electrical DfT & Fault Coverage Analyzer

    TestWay - ASTER Technologies

    TestWay's electrical DfT analyzer enables designers to validate designs at the schematic capture stage, to ensure that adequate measures have been included to comply with the manufacturers test requirements. The ability to verify that PCB designs have been developed with adequate Design-for-Test in mind, is key in determining the most effective test strategies and accurately calculating fault coverage, which is crucial in improving competitive advantage, lowering cost and ensuring product quality.

  • Process & Lab FTIR FT-NIR Analyzers

    Process Insights, Inc.

    Using a broad spectral region from the near-infrared to the mid-infrared, our Guided Wave ANALECT® Series of FTIR/FT-NIR analyzers measure physical and chemical properties of liquids, solids and gases. They are ideal for complex refinery applications such as fuels blending and component streams applications for polymers, petrochemicals, chemicals, pharmaceuticals in addition to general manufacturing. Customers include ADNOC, BP, CITGO, CPCL, Gazpromneft, HPCL, IOCL, Orpic, Phillips 66, Rompetrol, Statoil, PBF Energy and Tesoro.

  • Motor Exhaust Gas Sulfur Analyzer

    MEXA-1170SX - HORIBA, Ltd.

    The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.

  • Phase Noise Analyzer and VCO Tester

    FSWP - Rohde & Schwarz GmbH & Co. KG

    The R&S®FSWP phase noise analyzer and VCO tester features very high sensitivity thanks to extremely low-noise internal sources and cross-correlation. It can measure phase noise and amplitude noise in mere seconds on highly stable sources such as those in radar applications. Additional options such as pulsed signal measurements, residual phase noise (including pulsed) characterization and integrated high‑end signal and spectrum analysis make the R&S®FSWP a unique test instrument.

  • 110 GHz Lightwave Component Analyzer

    N4372E - Keysight Technologies

    The N4372E lightwave component analyzer helps you with optoelectronic tests with its measurement capability of 110 GHz in an extended wavelength range. It also offers RX testing up to 110 GHz in the full 1260 nm to 1620 nm range. It has a built-in optical power meter that enables you to check and control the operating power. The N4372E lightwave component analyzer's optical transmitter input port connects to an auxiliary tunable laser to verify S-parameters over wavelength.

  • Arc Infrared Carbon and Sulfur Analyzer

    CS-8620 - Wuxi Tianmu Instrument Technology Co., Ltd.

    Infrared carbon and sulfur analyzer is used together with high-speed automatic ignition furnace to quickly and accurately determines the mass fraction of carbon and sulfur in steel, iron, alloy, non-ferrous metals, cement, ore, catalyst and other materials. a high-tech product integrating light, electromechanical, computer and analytical technology. It has the advantages of wide measuring range, strong anti-interference ability, complete functions, simple operation, accurate and reliable analysis results, etc. It is the ideal for measuring Carbon and sulfur in many industries. Analytical equipment.

  • NIR & UV-VIS Process & Lab Analyzers

    Process Insights, Inc.

    Our Guided Wave complete analytical systems utilize proven Near Infrared (NIR) and Ultraviolet / Visible (UV-VIS) spectroscopic techniques. We deliver a total solution that includes optically matched components and a well-planned calibration approach leading to long-term success and savings. Our state-of-the-art systems are designed for continuous online use, providing real-time data of laboratory quality while thriving in the most demanding processing plant environments. We work with you to tailor a solution for your exact requirements from analyzer to interface.

  • Uni-Therm High Current Electrosurgical Analyzer

    Seward Medical

    A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.

  • UV Fluorescence Sulfur Dioxide Analyzer​

    Model T100 - Teledyne Monitor Labs

    The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software. ​

  • Analyzer for Total Sulfur in Gas Application

    TRACE S- 1000 - Atom Instrument

    The ATOM TraceS-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.The Model TraceS-1000 with EUVF is a field proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability. The TraceS-1000 is an excellent fit for applications in the 0-1ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The TraceS-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.

  • In-Situ Cross- Stack Laser Analyzer

    ABB Ltd.

    LS25 is an in-situ analyzer for non-contact measurement of the concentration of gases. The measuring principle of the LS25 is based on the principle of single line spectroscopy (Tunable diode laser absorption spectroscopy, TDLAS). A single cross-sensitivity-free absorption line of the gas to be measured is selected in the near infrared range. A single-mode diode laser operating at room temperature scans the respective absorption line. By using an opposite receiver, the absorption caused by the sample gas is measured and from this the concentration is calculated. An automatic correction for pressure and temperature changes is possible. In addition, the transmission is displayed respectively output as a signal for preventive maintenance.

Get Help