Filter Results By:

Products

Applications

Manufacturers

AC

Current Alternates direction of flow cyclically.

See Also: Alternating Current


Showing results: 406 - 420 of 2500 items found.

  • AC Magnetic Automatic Measurement Equipment

    ESS - TOEI INDUSTRY CO, LTD.

    This automatic measurement equipment to measure magnetic property in commercial frequency is used for quality control and research of materials. It is possible to apply single sheet sample and Epstein sample etc. Sine wave measurement can be made within the range of measurement frequency of 50Hz ~ 400Hz. Measurement of basic magnetic property [B,H,P,S,µ] can be made.

  • AC Fuel Flow Signal Generator

    TA-100 - Tech-Aid Products

    The TA-100 signal generator was designed to facilitate testing of aircraft fuel flow indicators that require two input signals designated as “Drum” and “Impeller”. This generator provides both signals so as to provide a direct interface to the fuel flow indicator under test. The generator also provides switched power out to the unit under test as well as a 5v source for testing the bezel lighting. The original design was built around the requirements for the AMETEK series indicators (pn: 10171 series). This generator simulates a reference and a time delayed signal of appropriate amplitude for an indication of up to 1200pph for the indicator under test. The “PPH Select” switch provides fixed signal delays representing 0, 200, 400, 800, 1000 and 1200pph flow rates respectively, this provides the mechanic with an expedient check of the indicators accuracy. The “PPH Adjust” control allows the mechanic to vary the signal delay throughout the full range and serves as a good method for checking of pointer smoothness from stop to stop. The unit’s front panel also provides test jacks to monitor the “FDR Output” as well as the drum and impeller signals. The TA-100 requires only 28Vdc to operate. This generator provides a very economical approach to any repair facility or flight department as it becomes an alternative to purchasing two bench top signal generators. The TA-100 generator at the very least can provide a simple functional test and eliminate the high cost of exchanging an indicator as a function of troubleshooting the aircraft system.

  • Dual-Range AC Voltage Detector with Flashlight

    Extech DV25 - Extech Instruments Corporation

    Model DV25 is a dual range NCV detector that combines two models into one. Low range measures down to 24 Volt and the high range measures up to 1000 Volt. Audible and visual indication, rugged double molded housing, and a bright built-in LED flashlight. Complete with 2 x AAA batteries.

  • AC / DC Digital Power Analyzer

    4016(800Vp,20Arms/200Ap) - PRODIGIT Electronics Co, Ltd.

    To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.

  • AC Resonant Test System for CVT

    XZB-H / 110 - Wuhan Huatian Electric Power Automation Co., Ltd.

    Adjustable resonance device for field calibration of capacitive voltage transformers up to 500kV.

  • AC Load Bank (Rack Mounted)

    K-1000 Rack Mounted - Kongter Test & Measurement Co., Limited

    Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.

  • AC Hysteresis Graph Test System

    DX-2012M - Dexing Magnet Tech. Co., Ltd

    Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

  • AC Hysteresis Graph Test System

    DX-2012SA - Dexing Magnet Tech. Co., Ltd

    Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.

  • Multi-output AC Power Supplies (CV/CF)

    PCR-LE2 Series - Kikusui Electronics Corp.

    The PCR-LE2 Series are designed based on the PCR-LE Series that supports single-phase output, single-phase 3-wire output, and three-phase output within the rated capacity by selecting the switch from the front panel operation.The PCR-LE2 series offer the same basic performance, using the common power unit of the PCR-LE Series, with providing easier installation and saving the space more efficiently compare to the individual allocation of the system for a single phase, single-phase 3-wire, and three phase systems. The lineup of PCR-LE2 Series are available in 5 models:6 kVA, 9 kVA, 12kVA, 18kVA, and 27 kVA model.

  • AC and DC Current or Voltage Transducers

    VT7 AND VT8 Series - Powertek LLC

    The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V

  • Resistive & Inductive AC Load Bank

    RL - Junxy Energy

    Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.

  • High Power Programmable AC Source

    61610 - Chroma Systems Solutions, Inc.

    Power Rating:61511/61611: 12KVA61512/61612: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • PWM Type AC Power Supply

    LSP-5KVA - Lisun Electronics Inc.

    • Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is  0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter  Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%

  • Single Phase AC Power Source

    APS51 Series - Twintex Electronics Co., Ltd

    ★ Full range adjustable output: Low 1-150V, High 150.1~300V, resolution 0.1V★ Output frequency: 45-250Hz★ Fast output key for 110V/220V and 50Hz/60Hz★ Panel lock function★ 3 sets memories for voltage and frequency settings★ Unlimited rotary knob for voltage and frequency adjustment, minimum step 0.001★ Strong overload capacity, overload 300% within 2s★ Withstand transient current 1.5 times of rated current within 0.1s★ Response time less than 20ms for 100% load and unload★ 5 digits high accuracy LED display for voltage, current, frequency, active power, power factor★ With soft-start function, set voltage rise time (0~99.999s), avoid damage by surge current during load start-up★ Over load, over current, over temperature and short circuit protections★ RS232 interface

  • AC High Voltage Breakdown Tester

    CIE / 5050A - Cambridge Instruments & Engineering Co.

    'CIE' A.C. High Voltage Breakdown Test Set is ideal for fast accurate & reliable testing of withstand/Breakdown test of electrical & electronic materials, components, equipments, panel boards, etc.