Filter Results By:

Products

Applications

Manufacturers

AC

Current Alternates direction of flow cyclically.

See Also: Alternating Current


Showing results: 2461 - 2475 of 2480 items found.

  • 20MHz 2-Channel Digital Oscilloscope

    Extech MS420 - Extech Instruments Corporation

    Extech's MS420 20 MHz 2-Channel Digital Oscilloscope offers a range of capabilities for effective troubleshooting of electronics and electronically controlled electrical systems. With 20 MHz bandwidth and conveniences like auto-set which optimizes the position, range, time base, and triggering to assure a stable display of virtually any waveform, the MS420 can be used in field repairs or bench duty. To identify subtle problems, Peak Detect features a fast 50 ns glitch capture. Core functions like XY Mode, FFT function, Trigger Hold off, Waveform Math, Averaging Mode and Persistence Mode all ensure you can confidently troubleshoot problems using a variety of approaches. To start up recurring testing routines, you can store and recall up to 4 waveform screens and setups to save time from job to job. This CAT II-rated oscilloscope extends its functionality with complete DMM functions that are displayed on the large 3. 8" (97mm) color LCD display. The MS420 comes with two 1X/10X oscilloscope probes, test leads, Windows XP/Vista compatible USB software and cable, capacitor measuring module, adjustment screwdriver, AC adaptor/charger, hard carrying case, user manual, and manufacturer's one-year limited warranty.

  • Coil Analyzers & Power Supplies

    IBEKO Power AB

    Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.

  • 3-Phase Power & Harmonics Analyzer - Complete with 3000A 24" Flexible Current Clamp Probes

    Extech PQ3350-3 - Extech Instruments Corporation

    Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

  • 3-Phase Power & Harmonics Analyzer - Complete with 1200A 12" Flexible Current Clamp Probes

    Extech PQ3350-1 - Extech Instruments Corporation

    Complete with 1200A 12" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case

  • Hybridization Oven

    REXMED ROV-200 - REXMED Industries Co., Ltd.

    MOD. ROV-200, AC 110/230V, Plug type: , Hybridization oven, HS CODE: 841780, UNCCS CODE: 484352, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~85˚C, Stability at 37˚C: ±0.1˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 1KW, Shaking timer: 999/min, 999/hr, shaking timer can be set in second, minute or hour function and at the end of operation audio and visual warning, Motor: Noiseless powerful brushless induction motor 15W, Rotation: 5~60rpm adjustable, Rotator: for 8pcs(optional), Reciprocal: 5~60rpm adjustable, Platform: L30 X W18cm(optional), Rocker: 5~60rpm adjustable, Platform: L29 X W22.5cm(optional), Chamber: L35 X W25 X H25cm, Capacity: 21.9L, chamber with glass viewing window, Optional: Rotator for 8pcs X 1set, reciprocal platform (L30 X W18cm) X 1set, rocker platform (L29 X W22.5cm) X 1set

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Vibration Diagnostics System

    VDS - Crystal instruments

    The Vibration Diagnostic System (VDS) is a vibration data management system designed specifically for the machinery Predictive Maintenance (PdM) community. It harnesses the graphic display capabilities of Crystal Instruments EDM Software for the work of machinery vibration analysts. It allows the user to quickly get to the data for a machine of interest and displays that data in the familiar Tri-axial or Single Axis view. Users can quickly compare other data from the same machine, quickly navigate back into the historical data of the machine, and quickly compare the data to that of other machines in the database. The software supports the construction of Average (a.k.a. baseline) data for a class of machines and allows easy comparison to that data as well. A full suite of cursors designed specifically for PdM analysis is provided for inuitive user interaction with the data.In addition to great graphics, an extensible machine modeling system was developed specifically for vibration analysis. VDS allows users to model machines based on the elements of the machine that can contribute to the vibration energy of the whole. Model bearings, rotors such as motor bars, couplings such as flexible and fluid couplings, account for slip in fluid couplings, model gears and pulley systems, and model turbines by accounting for each stage. The system is wide open, users can create new elements to use within a system. Users that may not want to do all that are provided with a comprehensive library of machine components such as AC and Induction Motors, Couplings, Gears, Pulleys, Pumps, and other components. Single and double gear shafts allows users to model many kinds of gear boxes with an unlimited number of stages. This ability alone lets users model their machines to view and use to keep track of vibration pickup locations, record the forcing frequencies of each part of the system, and attach attributes such as manufacturer and other part information.

  • Heavy Duty Dynamometers

    MD-250-HD - Mustang Dynamometer

    The MD-250-HD series dyno (SE/DE) was designed to be a performance dynamometer first with the added benefit of being able to test 2-wheel-drive heavy-duty vehicles such as truck, buses and commercial vehicles in addition to the standard car or light duty pick-up. The 250-HD is certified in the states of Colorado, Nevada and Utah for use in loaded-mode diesel smog testing programs because of its accuracy and reliability. No other dyno in its class offers more value or better in-house motor vehicle testing capabilities than the Mustang MD-250-HD. For starters, the MD-250-HD boasts a 1,500 horsepower measurement capacity at a top speed of 175 mph and a powerful air-cooled eddy current brake provides the MD-250-HD-SE with 900-hp worth ofloading capacity for steady state testing. Loading capacity can be increased to 1,500-hp via the optional DE model. The 250-HD can be upgraded to the 250-HD-SE-M via the addition of a 100 or 200 hp AC motor for transient testing of electric buses to measure range and regeneration or for emissions testing of IC engines. Do not be fooled by its compact size – the MD-250-HD is a serious dynamometer with serious tuning capabilities. The MD-250-HD uses a powerful eddy current power absorber, a frictionless, air-cooled braking device, to enable it to apply variable and steady state loading. A complete control and data acquisition system lets you design a wide range of tests or select from a host of pre-configured tests included with the standard system. The 250-HD’s four roller design makes setting up vehicles a snap – simply drive onto the 250-HD and let the tires settle in between the rollers. The 250-HD can be installed above-ground or below-ground, it’s your choice. The above-ground system utilizes an optional premium platform and ramp system with an above-ground restraint kit. The addition of an axle pull-down kit help keep the tires from slipping or trying to “climb out” of the rollers.

Get Help