  • Electrical Standards

    Fluke Calibration

    To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.

  • Hand-hold Field Intensity Meter

    LM870-H - Sichuan Jiuzhou Electronic Technology Co.,Ltd

    * Trunk-line AC voltage, V/A, C/N and TILT measurable* Automatic over-voltage shut-off protection* AC/DC optional (Ni-H/Li storage battery inside)* Full-digital key-board operation, direct freq. & channel input* Automatic scanning, Automatic channel-filtering, Automatic error-operation amending* All standard channels and subjoin channels pre-set inside* New channel-table setting according to user's special requirement* Character LCD displaying* English/Chinese operation interface* Audio output (speaker set-in)

  • Lightning Surge Generator

    SKS-0506IA - Shanghai Sanki Electronic Industries Co., Ltd.

    The lightning surge generator SKS-0506IA fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 6kV; both AC and DC samples can be tested. The rated voltage of the equipment under test can reach 380V, and the rated current can reach 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, higher intelligence and more user-friendly operation; the software is built with the level specified by the IEC standard Mode, can be called directly.

  • Portable AC/DC Power Supply

    UPS S3 - Manta Test Systems

    The Vanguard UPS S3 is an AC/DC adjustable output power supply designed to operate substation circuit breakers. The UPS S3’s AC and DC voltage sources can supply up to 10 Amperes during the circuit breaker coil energization and circuit breaker charging motor operation. Powered by a single phase 90-120 Vac voltage source, the UPS S3 provides an isolated adjustable AC/DC voltage source. Output voltages are variable via the front panel control knob.

  • Portable Multimeter

    Nanjing ELIKE Meter Co, Ltd.

    Basic functions:DC current: 200μA/20/200mA/10A AC, voltage: 200/600V DC, voltage: 200mV/2/20/200/600VResistor: Rx200/Rx2/Rx20/Rx200K/Rx2MSpecial functions:Diode transistor testContinuity buzzer low battery displayNegative polarity displaySelf-recovery protectionSampling frequency: 3 times/sMaximum display: 1999General characteristics:Product colors: iron-gray and orangeProduct net weight: approximately 115gLCD size: 53x33mmProduct size: 133x70x30mmPower: 1x9VPacking contents:Packing cartonHandheld bag English manualTesting lead batteryStandard individual packing carton size: 153x101x34mmCarton size: 560x325x340mm

  • Power RC Snubbers

    HK Film Capacitor Ltd

    Single phase and Three phase availableSuitable for AC and DC voltage applicationResistance and rate power of Resistor : 1 - 50W ( can be customized to 100W or above )Voltage: 63Vac, 125Vac, 280Vac, 480Vac, 500Vac, 600VacOperating temperature : -25~+85C / -40~+105CTesting Voltage : : 1.5 x Un 10sec ( can be customized )Varistor and Diode options available. Different applications can have very different electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.

  • PPS Clamp Transformer

    Techimp HQ S.r.L

    PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.

  • True RMS RF Millivoltmeter

    3440A - Ballentine Laboratories, Inc.

    The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.

  • Ultra Low Noise Preamp

    J2180A - PICOTEST Corp.

    The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.

  • 3 3/4 Digits AC/DC Current Digital-Clamp Multimeter

    KT7193 - Ketai instrument (kunshan) Ltd.

    ● 3 3/4 digits 3999 count● Extra high DC/AC current measurement● Data hold to capture measurements● Backlit display is easy to read under any light condition● AC current measurement up to 1500A● DC current measurement up to 1500A● DC/AC voltage, resistance, capacitance, frequency and temperature measurement● Diode and continuity test● Accessories included: 9V battery, carrying case, test leads, K typetemperature probe, English manual, gift box

  • Fan Type Ionizer

    ER-F - Panasonic Industrial Devices Sales Company of America

    With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.

  • Battery DC Resistance Analyzer

    KT-2004 - KILTER ELECTRONIC CO.,LTD

    ●DC pulse measure mode like battery real working state ●Special benefit to test online UPS battery with fluctuation charger●Effective eliminate the AC power supply with stable and accurate reading●Test range:200mΩ/2Ω/20Ω/200Ω●Max resolution:0.1mΩ●4 wire measurement●Voltage range:0.01V~19.99V●For Lead -acid,Lithium,Li-ion,Ni-HM and other types of batteries used ●Special benefit to online UPS battery with fluctuation charger

  • DSP Gaussmeter

    455 - Lake Shore Cryotronics, Inc.

    The Model 455 digital signal processing (DSP) gaussmeter combines the technical advantages of DSP technology with many advanced features at a moderate price. DSP technology creates a solid foundation for accurate, stable, and repeatable field measurements. Advanced features including DC to 20 kHz AC frequency response, peak field detection to 50 µs pulse widths, DC accuracy of 0.075%, and up to 5¾ digits of display resolution make the Model 455 ideal for both industrial and research applications.

  • PXI General Purpose 2A Relay Module 26xSPDT

    40-131-201 - Pickering Interfaces Ltd.

    These are low cost, general purpose electromechanical relay cards capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.

  • PXI General Purpose 2A Relay Module 16xSPDT, 50 D-sub

    40-131-001 - Pickering Interfaces Ltd.

    These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.