Showing results: 1831 - 1845 of 2500 items found.
-
Bender Inc.
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
AWG18 -
APPLICOS
The AWG18 is an 18 bit Arbitrary Waveform Generator for high-speed / high resolution waveform generation. This module features two dedicated signal paths. A DC to 100 MHz path which is optimized for accurate time domain and frequency domain measurements up to 30 MHz. And a dedicated AC path optimized for signals between 10 MHz to 100 MHz. In combination with the built-in filters it features a typical harmonics level of better than -80 dBc for the whole range.
-
Astronics Corporation
The CorePower® DC or AC Electronic Circuit Breaker Unit replaces conventional thermal mechanical circuit breakers and functions as both a breaker and a switch for controlling loads. By placing ECBUs closer to loads, aircraft manufacturers gain a significant reduction in wire weight, need fewer system components, and lower installation labor costs while increasing safety, efficiency, and reliability. This new smaller unit requires less space and provides more flexible mounting options.
-
287 SVD -
Standard Electric Works Co., Ltd
● Compact, easy to wear and convenient in use.● Usable both indoor and outdoor.● Voltage detection distance: 6.6kV(3.8kV phase to ground) : 40cm ± 20% 11.4kV(6.6kV phase to ground) : 55cm ± 20% 19.7kV(11.4kV phase to ground) : 80cm ± 20% 22.8kV(13.2kV phase to ground) : 85cm ± 20%● Water-proof design. (IP65)● Equipped with self-testing functions.● Able to sense all kinds of AC High Voltage System.● Low power consumption.● CE Certified.
-
Applied Relay Testing Ltd.
When used in conjunction with ART's own parametric relay test systems such as the RT290, the RT900 offers high speed AC and DC Hipot (dielectric withstand voltage) and Leakage testing of relays or other multi-pin passive devices.
-
ACD-50NAV -
Amprobe Test Tools
ACD-50NAV clamp-on power meter offers AC current measurements to 600 A, AC/DC voltage to 1000 V, and wide jaws to accommodate large conductors. This clamp-on multimeter is ideal for industrial power monitoring and verifying system conditions.
-
H301 -
Howell Instruments, Inc.
The H301 Environmental Control System (ECS) Tester measures and displays parameters required to test and troubleshoot aircraft heating and air conditioning systems. These parameters include temperatures, pressures, AC and DC voltages, DC currents, and resistances.
-
1800 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
-
1801 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
-
CTS Series 3.2 -
AMETEK Programmable Power, Inc.
The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.
-
AMM-1 -
D'Amore Engineering llc
The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)
-
KFM2150 System -
Kikusui Electronics Corp.
The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.
-
Model 610E -
TREK, INC.
The Trek Model 610E is a high-voltage power supply / amplifier / controller that is used in many applications including closed-loop charge control, electrophotographic research, insulation testing, dielectric material evaluation, and as an amplifier for AC or DC calibrators and power supplies.
-
MCH Instruments Co.,Ltd.
Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)
-
Computer Conversions Corporation
1.2VA, 1.5VA, 4.5VA and 5VA Models60 or 400, & 60 and 400 Hz. Models to 22 KHz.Trouble Free Isolated Reference Inputs & Signal OutputsUltra High Efficiency, Low DistortionSelf Powered off the AC Reference Input (DSP Series)Internal Cool AC-Pulsating Supplies (DSP Series)Very Low Loss & Heat DissipationFULLY INTEGRATED, NO EXTERNAL COMPONENTS REQUIREDVery High Resistance to Shock and VibrationHigh Reliability Throughout ImplementationIsolated, Transient, Therrnally & Short Circuit Protected Outputs