The company’s focus is in the field of test equipment designed for the purposes of testing electricity meters, current transformers and electrical network analysis. In addition, the company has developed a portfolio of equipment designed for testing water and heat meters.

  • 359/2/971-83-50
  • 359/2/971-84-19
  • emsyst@emsyst.com
  • “Tsarigradsko shousse” Blvd., 7th km, №133
    office 304
    BIC-IZOT, 1784
    Bulgaria

Filter Results By:

Products

Applications

Showing results: 1 - 11 of 11 items found.

  • Portable Three-Phase Current Load

    EE-120A-3 - EMSYST Ltd

    The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.

  • Portable Three-Phase Phantom Load

    EE-120A-3 + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.

  • Three-Phase Network Analyzer

    NET VISION 2010 - EMSYST Ltd

    NET VISION 2010 is a portable device designed for a quick and precise measurement of the electric values of a three-phase network. It is used by power engineers for check of AC motors, relay current protections, electricity meters, etc.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Portable Single-Phase Energy Standard

    PEWM-3C-1 - EMSYST Ltd

    The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.

  • Meter Test Benches

    TST 3/5 UNIVERSAL - EMSYST Ltd

    *A Three-Phase Voltage Generator EE-500 V for voltages up to 500Vac;*Five identical Modules EE-120A, each comprising three-phase current generators from 1 mA to 120A each) and Energy Standard Class 0.04;*Meter Suspension Rack with 5 positions for hanging the meter, Scanning Heads, Electronic Readers, Tariffs, Panic Button, Lamp;*PC with EE Software for control, memorizing, search and print of Reports.

  • CT Tester, Meter Tester, Circuit Analyzer

    GOLD MINER IV - EMSYST Ltd

    Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.

  • Portable Three-Phase Energy Standard

    PEWM-3C - EMSYST Ltd

    The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

  • Meter Test Benches

    Test Station - EMSYST Ltd

    The meter test station allows simultaneous testing of 3, 5, 10 or 20 induction or static electricity meters. The test station could be constructed for single-phase electricity meters or for three-phase meters.